Lpcb certified addressable fire alarm system fire alarm control panel for fire safety

  TX7004 Intelligent Fire Alarm Control Panel            Installation & Operation Manual                            

Featured Products


  TX7004 Intelligent Fire Alarm Control Panel
            Installation & Operation Manual  
                                                                                                                 
1 Introduction 
1.1 Overview 
The TX7004 comprise of a range of analogue addressable, microprocessor based fire alarm control 
equipment to offer flexibility in both design and operation. The System is modular concept for easy 
tailoring of system design, to meet the full requirements of the project. The TX7004 Intelligent Fire 
Alarm Control Panel is designed and manufactured to meet the requirement of BS EN54 Part 2&4. 
The TX7004 is designed to provide early warning fire detection, to quickly identify the location of fire 
and provide user definable text informing the occupants of the building of potential smoke spread. 
Simultaneously, the TX7004 will alert and evacuate the occupants, and control all necessary auxiliary 
command functions such as elevator control, air handling shut down, gas shut off & damper control, 
as per the cause and effects requirements configured though Command Builder Set-up. 
The TX7004 modular construction panel, capable of supervising four [4] monitored detection loops 
expandable up to six [6] loops on standalone basis. Each loop is capable to accommodate of 254 
addressable devices of any combination with T&A protocols, namely intelligent sounder strobe 
TX7300 & intelligent sounder TX7320 complying with EN 54-3, rate of rise and fixed temperature heat 
detector TX7110 complying with EN 54-5, photoelectric smoke detector TX7100 complying with EN 
54-7, intelligent manual call point TX7140 complying with EN 54-11, intelligent reflective beam 
detector (TX7130) complying with EN 54-12, input and output module TX7200, TX7210, TX7220 
complying with EN54-18, and loop isolator TX7230 complying with EN 54-17. The T&A devices are fully 
loop powered to support saving cost of the cable. 
These systems incorporate a number of features to allow easy operation through a user-friendly 
menu. The TX7004 has a LCD touch screen and Keypad menus for alternative operation with large 
button access to operate the keypad control by fire brigade personnel providing total user-friendly 
interface for browsing and programming. Added the commission features such as colour coded 
loop mapping, dual address and device mismatch monitoring, one-man test, simplified command 
builder's configuration that has proved to be highly rated by both commissioning and service 
engineers. 
The Control Panel has multiple built-in features. The loop card has built-in surge protection and the 
communication card interface support multiple interface protocol such as USB, Ethernet, CAN Bus, 
Serial, RS485, Fiber Optic in one singe card. The panel is Built-In Printer and 160 LED Zones Indicators. 
The panel provides variety of inputs and outputs interfaces and auxiliary such as Output to Sounder, 
F.P.E., Alarm and Fault output, Relays and Power Auxiliary. 

 Feature and Benefits 
Compliance EN54-2 & N54-4 
Using advance microprocessor technology with Large memory capacity 
Enhance user interface combining LCD Touch screen and keypad access 
Support real time visual algorithm 
Enhance false alarm prevention 
Keypad and PC programming 
Support Multiple interface protocol such as USB/Ethernet/Can Bus/Serial/RS485/Fiber Optic 
Support Loop Powered devices for extra saving on cable cost 
Built-In Printer and 160 LED Zones Indicators 
Commissioning Advantage 
Auto Enrolling of Devices 
Loop Mapping with colour coding status 
Monitor device mismatch and dual address conflict 
Command Builder to create requirements for fire event scenario 
With Loop protection against power surge 
One-man test with On/Off sounder 
Programming Protection 
System Capacity 
Up to 4 loop 
Support 254 Devices/One loop (1,016 ideal) 
Network up to 512 Node 
Programmable Capacity 
Zones up to 3000 
Sounders Groups 1-1000 
Other Groups 1001- 2000 
Built-in 160 LED Zones Indicator 
 
 Technical Specification 
Compliance EN54-2 & 4 
Input Voltage 230VAC +10%-15%, 50Hz 
(120VAC, 60Hz, it is not applicable for EN54 & Not 
tested by LPCB) 
Input Current Consumption 1A 
PSU Output To CIE 21.5~28.5VDC 
Batteries Maximum Charge Capacity: 2 x 12V / 28AH 
 Maximum Charge Current: 1.2A 
I maxA: 0.93A 
I maxB: 2.53A 
Minimum Quiescent Current: 0.45A(Imin) 
Maximum Internal Resistance: 1.0OM
Rechargeable-Lead acid type battery 
Recommended manufacturer 
and model of battery: PS-12280 12V28AH (Tested With CIE By LPCB) 
Networking and Interfaces 
Panel to panel communication Can Bus [loop] 
Number of Panels 512 
Interface Port USB, RS485 Serial, RS232 Serial, Ethernet 
System Capacity 
Memory [Non-Volatile] 1000 Fire Events, 10,000 General Event 
Zones 3,000 programmable 
Total Group 3,000 programmable 
Sounder Group 1,000 programmable 
Common Group 2,000 programmable 
Loop Specifications 
Protocol/Addressing T&A, Value range from 1 to 254 
No. of Loop 4 Loop 
Protection Built-in 4kV Surge protection 
Power rating 16~24Vdc /120mA 
Cabling 1.0Km Max Length/2 x 1.5mm²solid core Fire resistance 
Recommended Wiring (subject to local installation codes) 
ISST-SFR3/ 711c-(cl-5) Intelligent Safety & Security Technology Limited 
NoBurn XPS/ 682e/01 Ventcroft Limited 
FT30 SAFFIRE/ 1134j Draka UK Limited 
Context Plus/682a-(cl-3) Context Plus Ltd 
FP200 Gold LSOH/ 077k/01 Prysmian Cables & Systems Limited 
 And all LPCB approved Fire cables 
 Recommended Cable Length ≤1000m 
Panel Input/outputs 
Programmable Relays 4 circuits: Normally Open/Close 
Programmable Input 1 Circuit: Current Limited 24Vdc (for future use) 
Programmable Auxiliary Power 19~28Vdc (Current Limited) 
Fixed Outputs (FPE/Sounder) 2 Circuits: 18~28Vdc (Current Limited) 
Indicator 24 LED Status/ 160 Zone Indicators 
Display 7" TFT Touch Screen 
Keypad 5 Brigade buttons and Programming Keypad 
Material / Color Flat sheet Metal / with outer glass door, Orange stripe 
Dimension Lx W x H 530 mm x 490 mm x 135 mm 
Weight 16.70 Kg 
Temperature -5ºC~+40ºC
Humidity 0 to 95% Relative Humidity, Non condensing 

Lpcb Approval Addressable Fire Alarm System Fire Alarm Control Panel for Fire Safety
 